Product Description
The PHCC Pro Series PS-C22 Combination Backup and Primary Sump Pump System comes pre-assembled with check valves installed, weep holes drilled, and is plumbed and mounted on a platform for quick and easy installation. The energy efficient primary AC sump pump will provide 2,770 GPH (46.2 GPM) at a 10 ft. lift and its caged dual float (DFC1.5) will deliver years of dependable service. The backup sump pump will protect from power outages, primary AC sump pump failure, primary AC float failure and provide extra capacity if needed. Plus, when maintenance is needed or a problem arises, it sounds an alarm, pinpoints problems, provides solutions on the control panel, and (using one of the Pro Series Connect Modules) can alert remotely via, text, email or in app notification. The backup system delivers 1,850 GPH (30.8 GPM) of pumping capacity at a 10 foot lift and will pump intermittently for days on a single charge of the Pro Series battery.Pre-assembled Pro Series ST1033 sump pump, enhanced dual float switch and a Pro Series 1850 backup sump pump systemAC primary sump pump capacity: 2,770 GPH (46 GPM) at 10 ft. liftBackup sump pump capacity: 1,850 GPH (30.8 GPM) at 10 ft. lift2 sets of dual float switches for 4 times the protectionBackup system monitoring controller detects irregularities, sounds an alarm, pinpoints problems and solutions on the control panelAlerts if AC power is out or the circuit breaker has trippedMonitors the battery and alarms if maintenance or replacement is neededUSB data port and remote terminals connect to external prodices such as a Pro Series connect module, home automation systems or other prodices for remote notificationBackup pump will assist primary pump if excessive amounts of water are entering the sump pitBattery backup system pumps intermittently for days on a single chargeAutomatically switches to battery power when AC fails1.6 Amp charger automatically recharges and maintains the batteryDesigned for use with maintenance or maintenance free batteriesFluid sensor will monitor the water level of a Pro Series wet cell battery (B2200 or B1000)Warning alarms can be temporarily silenced during a power outageBoth primary and backup pump run weekly tests to exercise and check for proper operationIncludes: backup pump, monitoring control box with dual float switch and fluid sensor, charger, battery box, primary AC pump, enhanced dual float controller with caged dual float (DFC1.5), and two check valves pre-assembles on a sump footProduct Videos
Custom Field
UNSPSC Code 40151512